Natural Gas

NG Service Installation and Connection
Natural gas installation of this appliance must conform
with local codes or, in the absence of local codes,
to the national fuel gas code, ANSI Z223.1a-1998.
Installation in Canada must be in accordance with
the standard CAN/CGA-B149.2, Propane Installation
Code.
You do not need to hire a contractor to install your
natural gas service, but you need to make sure you
have all required permits and ensure the installation
complies with State and local code. We recommend
you hire a certified contractor if you do not wish to do
the installation yourself.
The natural gas pipe from your house to the
location of your barbecue island needs to be ¾" and
terminate with a shut-off valve with a ½" male fitting.
Check with a contractor or your local inspector for
requirements.
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the grill
is manufactured for.
NG Regulator
The grill for use with natural gas comes equipped
with its own regulator that MUST NOT be removed.
If this regulator needs to be replaced, use only the
type specified by for this appliance.
IMPORTANT: Never connect the grill to an
unregulated gas supply .
Shut-off Valve
Ensure that the service supplying the grill is fitted
with a shut off valve conveniently positioned near
the grill and giving ease of access.
The grill must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 0.5
psi (3.5 kPa).
P4 and P5 Barbecue Grills
LTR50001137, Rev. C
9
www.calflamebbq.com