Natural Gas Installation - Cal Flame Chef C100 User Manual

Barbecue islands
Hide thumbs Also See for Chef C100:
Table of Contents

Advertisement

120 Volt Electrical Installation
For 120V grills, you need a dedicated 120V 20 amp grounded
electrical service.
There will be a 110V power outlet inside the barbecue island.
Using romax or similar grounded, shielded wire, connect the outlet
to the electrical service in the stub-up.
If the circuit breaker trips while the barbecue island is in use, reset
it. If it does not reset, contact a licensed electrician for service. DO
NOT USE THE BARBECUE ISLAND!
240 Volt Electrical Installation
If you have an electric grill, you will also require a 240V 50 amp
grounded electrical service in addition to the 110V service.
The electric grill needs to be permanently wired to the 240V
service. Using romax or similar grounded shielded wire, connect
the wires from the grill to the 240V service in the stub-up.

Natural Gas Installation

You do not need to hire a contractor to install your natural gas
service, but you need to make sure you have all required permits
and ensure the installation complies with State and local code. We
recommend you hire a certified contractor if you do not wish to do
the installation yourself.
If your dealer is not a certified contractor, you will need to hire a
contractor for installation of your gas service.
The natural gas pipe from your house to the location of your
barbecue island needs to be ¾" and terminate with a shut-off
valve with a ½" male fitting. Check with a contractor or your local
inspector for requirements.