Key Functions; Engineer's Reset; Loading Defaults - Menvier Security TS510 Installation & User Manual

Hide thumbs Also See for TS510:
Table of Contents

Advertisement

TS510 & TS500
Defaults
ENGINEER CODE
MASTER USER CODE
LAST EXIT ZONE
ACCESS ZONE
EXIT TIME
ENTRY TIME
BELL DURATION
BELL DELAY
REMOTE RESET REF

Key Functions

Engineer's Reset

1.
Enter Engineer code default 1234. The CALL ENGR
LED will illuminate. You are now in Engineer mode.
2.
Press 0 twice to return to unset.

Loading Defaults

1.
Power down panel mains and battery.
2.
Wire in a small piece of cable across two terminals
for exit terminator.
3.
Power up battery and mains.
4.
Enter 1234 and remove link.
5.
The panel is now back to Factory Default
Programming.
TS510 & TS500
= 1234
OPTIONS 1: (NOT APPLICABLE TO TS500)
= 5678
Bell output is SAB
= ZONE 1
Alarm cleared on reset
= ZONE 2
Audible P.A.
= 30 secs.
P.A. audible in line fault
= 30 secs.
Fire output signals during Full Set only
= 20 min.
Output 1 is WALK TEST
= 0 min.
Output 2 is SW12V
= 004
KEY SW/F.EXIT input is
full set keyswitch Set inhibited on mains fail
OPTIONS 2: (NOT APPLICABLE TO TS500)
Exit Terminator chimes
Exit Terminator disabled
Timed exit set
Auto rearm
User reset
Bell Test/Walk Test
Please refer to user function numbers 1 & 2
respectively.
6 of 10
496525 Issue A