Fault Finding - Menvier Security TS510 Installation & User Manual

Hide thumbs Also See for TS510:
Table of Contents

Advertisement

TS510 & TS500
(FLASHING=OMITTED, UNLIT=NORMAL)
5.
When satisfied press [0] (END).
6.
Two tone confirmation sound heard - [UNSET]
will illuminate.

Fault finding

[CALL ENGR] flashing
Indicates there is a telephone line problem if
you are connected to a monitoring station.
Check telephone and call engineer.
[CALL ENGR] illuminated
Try re-set procedures or call engineer.
[TAMPER] illuminated or flashing
The panel sounder will probably be bleeping
and a zone light: may be flashing.
1.
Enter passcode to stop sounder
2.
Check detection devices in zone indicated
3.
If you can correct the fault do so and then
enter your passcode and press [0] (END).
System returns to UNSET
4.
If fault cannot be remedied - call your
engineer.
(PA) illuminated
1.
Manually reset Panic button with the key
provided
2.
Enter your passcode - PA indicator on
3.
Enter your passcode and press [0] (END).
[POWER] light out
This will occur if there is a mains failure or power cut
when the system will switch to reserve battery power
for about 8 hours. If the power cut persists the system
will go into alarm. If this happens enter your passcode
to unset the system and call your engineer.