Panasonic PT-DX820 Operating Instructions Manual page 154

Hide thumbs Also See for PT-DX820:
Table of Contents

Advertisement

7
[E-MAIL ADDRESS 1], [E-MAIL ADDRESS 2]
Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS
2] blank when two E-mail addresses are not to be used.
[Authentication set up] page
Set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail.
Click [Detailed set up] → [Authentication set up].
1
[Auth]
Select the authentication method specified by your Internet
service provider.
2
[SMTP Auth]
Set when the SMTP authentication is selected.
3
[POP server name]
Enter the POP server name.
Allowed characters:
Alphanumerics (A - Z, a - z, 0 - 9)
Minus sign (-) and period (.)
4
[User name]
Enter the user name for the POP server or the SMTP server.
154 - ENGLISH
Chapter 4 Settings — [NETWORK] menu
7
8
8
Settings of the conditions to send E-mail
Select the conditions to send E-mail.
[MAIL CONTENTS]:
Select either [NORMAL] or [SIMPLE].
[ERROR]:
Send an E-mail when an error occurred in the self-test.
[LAMP1 RUNTIME]:
Send an E-mail when the remaining lamp runtime for the lamp 1
has reached the value set at the right field.
[LAMP2 RUNTIME]:
Send an E-mail when the remaining lamp runtime for the lamp 2
has reached the value set at the right field.
[INTAKE AIR TEMPERATURE]:
Send an E-mail when the intake air temperature has reached
the value set at the above field.
[PERIODIC REPORT]:
Place a check mark on this to send an E-mail periodically.
It will be sent on the days and time with the check mark.
9
[Submit]
Update the settings.
1
2
3
4
5
6
7
8
5
[Password]
Enter the password for the POP server or the SMTP server.
6
[SMTP server port]
Enter the port number of the SMTP server.
(Normally 25)
7
[POP server port]
Enter the port number of the POP server.
(Normally 110)
8
[Submit]
Update the settings.
7
8
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dw750Pt-dz780

Table of Contents