When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to [AUTO] and [LINK] is set to [OFF]
The screen shows the status of the brightness control in one projector
When [MODE] of [BRIGHTNESS CONTROL SETUP] is set to [PC]
1
Display the name of the projector.
2
Display the synchronized group.
3
Display the IP address of the projector.
4
Display the names and IP addresses of projectors in same group detected over the network.
5
Display the status by color.
Green: There is an allowance for brightness correction.
Yellow: There is little allowance for brightness correction.
Red: There is a brightness control error.
6
Display error detailed messages.
7
Display error messages.
When the message [Failed to apply BRIGHTNESS CONTROL to some projectors.] appears, it means that synchronization with the
projector displayed in red has failed.
Press as to select the projector displayed in red, and press the <ENTER> button to display the error details.
8
Update to the latest status information.
r Error details
Error message
[Exceed maximum number of
projectors.]
[Please check the COMMAND
CONTROL setting.]
[Please check the USER NAME
and PASSWORD in the COMMAND
CONTROL setting.]
[Cannot apply BRIGHTNESS
CONTROL. Please check projector
status.]
[Brightness Sensor Error]
*1 "Multi Projector Monitoring & Control Software" is included in the supplied CD-ROM.
Note
f If the synchronized projectors are not displayed in the list, check the following:
g Are there devices with the same IP address on the network?
g Are the LAN cables connected correctly? (x page 142)
g Are the subnets of the projectors the same?
g Are the same [LINK] settings applied to a group?
f Refer to [NETWORK SETUP] (x page 139) or "[Network config] page" (x page 151) on how to change the projector name.
Chapter 4 Settings — [PROJECTOR SETUP] menu
BRIGHTNESS CONTROL STATUS
LINK
PROJECTOR
RETURN
MENU
BRIGHTNESS CONTROL STATUS
MODE
PROJECTOR
RETURN
MENU
f Limit the number of projectors in one group to eight.
f When synchronizing nine or more projectors, use the dedicated software "Multi Projector
Monitoring & Control Software"
f Set [NETWORK CONTROL] → [COMMAND CONTROL] to [ON] for the projector in error.
f Set [NETWORK CONTROL] → [COMMAND PORT] of all projectors to be linked to the same value.
f Assign the same [User name] and [Password] strings that have web control administrator rights to
all projectors to be linked.
f The projector is in standby. Switch on the power.
f There is a problem with the brightness sensor. If problems persist even after switching on the
power, consult your dealer.
OFF
5
1
6
PC
5
1
6
Measures to take
through a computer.