3)
Press qw to switch the pages.
f The page will change each time you press the button.
[PROJECTOR TYPE]
[PROJECTOR RUNTIME]
[LAMP1]
*3
[LAMP2]
*3
[MAIN/SUB VERSION]
[INTAKE AIR TEMP.]
[OPTICS MODULE TEMP.]
[EXHAUST AIR TEMP.]
[COOLING CONDITION]
[ATMOSPHERIC PRESSURE] Displays the atmospheric pressure.
[SELF TEST]
[INPUT]
[BACKUP INPUT STATUS]
[SIGNAL NAME]
[SIGNAL FREQUENCY]
[NUMBER OF REGISTERED
SIGNAL]
[REMOTE2 STATUS]
[AC VOLTAGE]
[LAMP UNIT MODEL NO.]
[LAMP1 SERIAL NUMBER]
[LAMP2 SERIAL NUMBER]
[UPGRADE]
*2
[ON COUNT]
[LAMP1]
[LAMP2]
[SIGNAL INFORMATION]
*1 The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
*2 Only for PT-DZ780
*3 The lamp runtime to be displayed is real time. The following conversion is required to calculate the rough estimate for lamp replacement.
(A x 6 + B x 4) ÷ 6
f A: Runtime when [LAMP POWER] is set to [NORMAL]
f B: Runtime when [LAMP POWER] is set to [ECO]
Chapter 4 Settings — [PROJECTOR SETUP] menu
Displays the projector type and serial number of the projector.
Displays the runtime of the projector.
Displays the runtime and status of the lamp 1.
Displays the runtime and status of the lamp 2.
Displays the main and sub versions of the firmware of the projector.
Displays the status of the intake air temperature of the projector.
*1
Displays the status of the internal temperature of the projector.
*1
Displays the status of the exhaust air temperature of the projector.
*1
Displays the set cooling conditions. When [AUTO] is set, automatically recognized result is displayed.
Displays the status of the projector.
Displays the input terminal currently selected.
Displays the backup status.
Displays the input signal name.
Displays the frequency of the input signal.
Displays the number of registered signals.
Displays the control status of the REMOTE2.
Displays the status of the AC voltage.
Displays the model no. of the lamp unit.
Displays the serial number of the lamp 1.
Displays the serial number of the lamp 2.
[ET-UK20]
[ET-CUK10]
[POWER ON TIMES]
[LAMP1 ON]
[LAMP2 ON]
[SHUTTER]
Displays the runtime in detail.
Displays the runtime in detail.
[MEMORY NO.]
[INPUT]
[SIGNAL NAME]
[SIGNAL FREQUENCY]
[SYNC.STATE]
[V.SYNC WIDTH]
[SCAN TYPE]
[TOTAL DOTS]
[DISPLAY DOTS]
[TOTAL LINES]
[DISPLAY LINES]
[SAMPLING]
[SIGNAL LEVEL]
[BIT DEPTH]
*2
Formula for lamp replacement time (rough estimate)
Displays the activation status based on the Upgrade Kit (Model No.:
ET-UK20).
Displays the activation status based on the Auto Screen Adjustment
Upgrade Kit (Model No.: ET-CUK10).
Displays the number of times the power is turned on.
Displays the number of times the lamp is turned on.
Displays the number of times the shutter is closed.
Displays the memory number of the input signal.
Displays the input terminal currently selected.
Displays the input signal name.
Displays the frequency of the input signal.
Displays the synch polarity of the input signal.
Displays the vertical sync signal pulse width of the input signal.
Displays the scan type of the input signal.
Displays the total dot count of the input signal.
Displays the number of input signal display dots.
Displays the total line count of the input signal.
Displays the number of input signal display lines.
Displays the sampling information of the input signal.
Displays the signal level of the input signal.
Displays the gradation of the input signal.
ENGLISH - 123