Power supply units

Safety notes
V
CAUTION!
Do not disassemble the power supply unit. Doing so may cause
electric shock.
Areas around the power supply unit may remain extremely hot after
shutdown. After shutting down the server, wait for hot components to
cool down before removing the power supply unit.
When installing a power supply unit, ensure that the connector of the
power supply unit is not damaged or bent.
If the power supply unit is hard to remove, do not pull it out by force.
The power supply unit is heavy, so handle it carefully. If you drop it by
mistake, injuries may result.
For further safety information, please refer to chapter
information" on page
6.1

Basic information

The PRIMERGY RX4770 M1 server can be equipped:
– with up to four power supply units that automatically adjust to any mains
voltage in the range of 100 VAC to 240 VAC (only 1200 W PSUs)
or
– with up to four power supply units that automatically adjust to any mains
voltage in the range of 200 VAC to 240 VAC (only 1600 W PSUs).
I
Power redundancy is possible with two or more power supply units. The
effective power of the power supply units may not differ.
V
CAUTION!
The server supports a mains voltage in the range of 100 VAC to 240 VAC
(only 1200 W PSUs) respectively in the range of 200 VAC to 240 VAC
(only 1600 W PSUs). You may only operate the server if its rated voltage
range corresponds to the local mains voltage.
RX4770 M1
31.
Upgrade and Maintenance Manual
"Important
89