Power; 3-4 Drive Carrier Leds; Sas Drives (6015C-M3); Sata Drives (6015C-Mt) - Supero SUPERSERVER 6015C-M3 User Manual

Table of Contents

Advertisement

Power

Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.

3-4 Drive Carrier LEDs

SAS Drives (6015C-M3)

Each SAS drive carrier has two LEDs:
Green:
When illuminated, the green LED on the front of the SAS drive carrier
indicates drive activity. A connection to the backplane enables this LED to blink
on and off when that particular drive is being accessed.
Red:
The SES2 compliant backplane activates the red LED to indicate a drive
failure. If one of the SAS drives fail, you should be notifi ed by your system
management software. Please refer to Chapter 6 for instructions on replacing
failed SAS drives.

SATA Drives (6015C-MT)

Each SATA drive carrier has two LEDs.
Green:
When illuminated, the green LED on the front of the SATA drive carrier
indicates drive activity. A connection to the SATA backplane enables this LED
to blink on and off when that particular drive is being accessed.
Red:
The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a SATA drive fails, you
should be notifi ed by your system management software. Please refer to Chapter
6 for instructions on replacing failed SATA drives.
Chapter 3: System Interface
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 6015c-mt

Table of Contents