Control Panel Leds; Overheat/Fan Fail; Nic2; Nic1 - Supero SUPERSERVER 6015C-M3 User Manual

Table of Contents

Advertisement

S
S
UPER
ERVER 6015C-M3/6015C-MT User's Manual
3-3

Control Panel LEDs

The control panel located on the front of the SC813MTQ-520C chassis has fi ve
LEDs. These LEDs provide you with critical information related to different parts of
the system. This section explains what each LED indicates when illuminated and
any corrective action you may need to take.

Overheat/Fan Fail

When this LED fl ashes, it indicates a fan failure. When on continuously it indicates
an overheat condition, which may be caused by cables obstructing the airfl ow in
the system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing
or on as long as the indicated condition exists.
2

NIC2

Indicates network activity on LAN2 when fl ashing .
1

NIC1

Indicates network activity on LAN1 when fl ashing.

HDD

Channel activity for all HDDs. This light indicates DVD-ROM and SAS/SATA drive
activity on the 6015C-M3/6015C-MT when fl ashing.