Response: A valid command will write the CAN configuration baud
rate into the EEPROM and then reboot the I-7530 module.
Note: It is necessary to enable the "Error Response" function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
Example:
Command: P14<CR>
Set the CAN baud rate=125K into the I-7530 module and then
reboot the I-7530 module.
4.9 RA[CHK]<CR>
Description: Reboot the I-7530 module. If the module is displaying on but
the CAN bus is off, users can use this command to reboot the module in
order to allow it to work in order again.
Syntax: RA[CHK]<CR>
RA
Response: Valid command will reboot the I-7530 module.
Note: It is necessary to enable the "Error Response" function in the I-
7530 Utility, in order to receive Syntax and/or communication error
information at the host PC.
Example:
I-7530 RS-232/CAN Converter User's Manual (Version 2.0, Sep/2007) ------------- 33
Table 10: CAN baud rate list
10K baud rate of CAN
20K baud rate of CAN
50K baud rate of CAN
100K baud rate of CAN
125K baud rate of CAN
250K baud rate of CAN
500K baud rate of CAN
800K baud rate of CAN
1000K baud rate of CAN
Invalid command: ?<Error Code><CR>