Martin Easypix User Manual page 40

Table of Contents

Advertisement

Construction
Luminaire
Housing .............................................................................................. Aluminum
Finish .......................................................................................... Clear anodized
Front cover .............................................................................................. PMMA
IP rating ...................................................................................................... IP20
Easypix Power
Housing ...................................................................................................... Steel
Finish .............................................................................................. Grey coated
IP rating ............................................................................... For indoor use only
Installation
Orientation .................................................................................................... Any
Vertical aiming ......................................................................................... +/- 95°
Mounting points ............................ Mounting brackets or 35 mm DIN top-hat rail
Maximum connected number of luminaires per Easypix Power
Easypix 300 luminaires ................................................................................... 24
Easypix 1200 luminaires ................................................................................... 6
Mixture of Easypix 300 and 1200 (max. length) ................................. 7.2 meters
Connections
Easypix Power mains input ............................................. Male (C14) IEC socket
Easypix Power data input and output ....................................................... RJ-45
Easypix luminaire connection ............................. 13-pin DIN power/data system
Electrical
AC power .............. Switch-selectable 100-120/200-240 VAC nominal, 50/60 Hz
Main fuse .............................................................................. 5.0 AT (slow blow)
Thermal
Cooling ................................................................ All devices convection-cooled
Maximum ambient temperature (T
Minimum ambient temperature (T
Max. surface temperature, steady state ..... Luminaire, T
40
max.).................................... 40° C (104° F)
a
min.).......................................... 5° C (41° F)
a
Easypix user manual
=40° C: 65° C (149° F)
a

Advertisement