FEATURES:
1.
Standard
2.
Easy motor direction change
3.
Auto close facility (Infra red beams must be fitted if auto close is activated).
4.
Condominium / Free exit loop facility
5.
P.I.R.A.C (Passive Infra Red Access Control) facility
6.
Slowdown (Ramp down) facility
1.
Standard Mode (No function selected)
When the gate is activated it will open and can be stopped in mid cycle by pressing the
transmitter or manual push button. Pressing the transmitter or push button can reverse the
gate. In standard mode the gate will remain on its open limit until it is triggered to close.
If main power fails, the motor will still operate until battery reaches 20 volt. Gate will then
remain close. Change to manual by overriding the motor by the override lever. When the
main power comes on again, lock in the override lever and the motor will function as
normal.
2.
Easy motor direction change (Dipswitch 2)
By selecting the dipswitch, the motor direction and the limit wires are changed
automatically. Dipswitch ON, gate closes to the right. Dipswitch OFF, gate closes to the left.
(This can only be changed before programming or if neither limit switches are activated).
3.
Auto close (Dipswitch 3 ON) (Infra red beams must be fitted if auto close is activated).
When Auto close is activated and the Gate opens to the open limit, the gate will wait the
pre-programmed time before automatically closing. If the gate is triggered while the gate is
in its closing cycle it will stop and reopen.
To override the auto close wait till the gate reaches its open limit then press & hold the
transmitter or manual push button for 5 sec. (The control card will give 1 long beep to
confirm the override) To reactivate the auto close, press the transmitter or manual push
button.
If the transmitter or manual push button is pressed while the gate is in its opening cycle, the
gate will close after the preprogrammed auto close time (from any position, not only from
the open limit)