DTS 512 Installation Manual

Sliding gate motor
Hide thumbs Also See for 512:

Advertisement

DTS 512/624
SLIDING GATE MOTOR
INSTALLATION MANUAL
DTS SECURITY
P.O.BOX 3399
Base plate-mounting instructions
EDENVALE
TELEPHONE 086 1000 387
Spartan
Pretoria
Alberton
E-EEEE
www.dtssecurity.co.za
1
1610
+2711 392 5540 (H/O)
+2712 548 2336
+2711 907 8846

Advertisement

Table of Contents
loading

Summary of Contents for DTS 512

  • Page 1 DTS 512/624 SLIDING GATE MOTOR INSTALLATION MANUAL DTS SECURITY P.O.BOX 3399 Base plate-mounting instructions EDENVALE 1610 TELEPHONE 086 1000 387 Spartan +2711 392 5540 (H/O) Pretoria +2712 548 2336 Alberton +2711 907 8846 E-EEEE www.dtssecurity.co.za...
  • Page 2 BASE PLATE MOUNTING INSTRUCTIONS 1. Assemble base plate by fastening M10x30 Hex set screws into base plate from under the base plate up and tightening into position. 2. Mount base plate with bolts 160mm from the centre of the gate track and centre of base plate a minimum of 250mm away from the gate opening.
  • Page 3: Rack Mounting Instructions

    Gearbox mounting instructions 1. Fit gearbox over mounting bolts protruding from base plate. 2. Slide gate fully open and closed, insuring pinion gear has approximately 5mm clearance to gate at all times. 3. Fasten gearbox down firmly to base plate using M10 washers and nuts. How to override the gate motor for manual operation 1.
  • Page 4: Power Connections

    Low voltage (OBT) (25 VA) transformer – 220V at gate. (DTS512 has a 500m/Amp fuse) Connect 220V AC to input side of 512/16volt or 624/24volt AC transformer (black & brown wires), or to NEL (Neutral/Earth/ Live) connector on side of transformer, then connect the output wires (red) to 16/24V AC connectors on controller card.
  • Page 5 High access power supply unit – 220V at gate. (DTS512, 220VA has a 2 Amp fuse and the DTS624, 120VA has a 1.5 Amp fuse) Connect 220V AC to LEN (Live/Earth/Neutral) connector on side of power supply unit. Black lead from power supply unit gets connected to – ( neg.) PSU connection on PCB. Red lead from power supply unit gets connected to + ( pos.) PSU connection on PCB.
  • Page 6: Wiring Diagram

    Note: If sentry beams are fitted, then S/BEAM, N/O on the PCB must be connected to N/C on the RX with the pins not bridged and N/O if the pins are bridged. (Please note that the 12V OUT on the 512 PCB’s is an unregulated voltage up to 22Volt DC on PCB’s up to S/N 01622836).
  • Page 7: Programming

    PROGRAMMING 1 – Run Time (Calibrating) Setup (With total power up, AC and DC, on PCB)  Unlock and open the override lever on the gearbox.  Open the gate manually approximately 1metre.  Close and lock the override lever on the gearbox. (PCB should beep 1-5 beeps pending on load pot setting).
  • Page 8: On Board Receiver Programming

    Load setting To adjust the load, turn the provided load pot to determine the load setting (Minimum, anticlockwise & Maximum, clockwise). The control card will beep, 1 minimum to 5 maximum beeps on next trigger before movement. ON BOARD RECEIVER PROGRAMMING The onboard receiver is designed to work with most rolling code transmitters.
  • Page 9 Auto close cannot be over ridden in condominium mode. (No party mode). If main power fails, the motor will still operate until battery reaches 9.5/19 volt. (9.5 volt for 512 and 19 volt for 624 motors) Gate will then remain open.
  • Page 10 6. Slowdown (Dipswitch 6) With dipswitch selected ON, the gate will have a long close and open controlled slow down distance of 800mm and with the dipswitch OFF, the close and open controlled slow down distance will remain the same unless programmed to a shorter distance. (Contact the supplier for instructions to this programming).
  • Page 11 Five 1 second beeps - Holiday lockout mode has been de-activated. Twenty 100ms beeps - Motor has stalled or overloaded, then check the following points: 1) Gate pulling force (should not exceed 512/12.5kg or 624/15kg) 2) Load pot is set too low (Turn pot completely clockwise) 3) Battery voltage under load (512/12volt or 624/24volt) (Not connected) 4) Gearbox gearwheel.
  • Page 12 (ZERO voltage). If not, a gate relay module must be fitted. Note; 1) The 12V OUT on the 512 PCB’s is an unregulated voltage up to 22Volt DC. (New 512 version with 2 regulators will have a regulated 12 volt AUX output) 2) The 624 H/A model will have a wire connected from battery positive to the transformer.
  • Page 13: Troubleshooting

    TROUBLESHOOTING SYMPTOMS CAUSES ACTION When pressing the remote Transmitter battery flat. Replace transmitter battery. transmitter or manual push button the gate operator will Transmitter or manual push Check with supplier. button is physically damaged. not respond at all. Transmitter has not been Follow the receiver setup programmed into the receiver instructions.
  • Page 14 The gate opens but will not The primary supply has failed Check the household main and the unit is running on supply, the transformer or close. battery reserve with the PSU and all related cabling. condominium/loop option selected and it has reached its low battery limit (9.5 or 19 Volt).
  • Page 15 The unit gives two short 1 The pedestrian (PT) mode on Check equipment /cabling second beeps and opens the PCB is being triggered. attached to the pedestrian (PT) partially and stops, gives two on the PCB input. short 1 second beeps and A transmitter code has been Delete the transmitter and re- then closes.
  • Page 16: Manufacturer's Warranty

    (Remote batteries are consumables and therefore carry NO warranty)  All goods are warranted to be free from faulty components and manufacture.  Faulty goods will be repaired or replaced at the sole discretion of DTS Security Products, free of charge.