1 – Run Time Setup (This will automatically happen when triggered after total power up or
Gate approximately 1metre open
With all dipswitches OFF (excluding dipswitch 2 pending motor direction), press & release
Bt/SET button.
Gate will close, open and close again and stop on close limit (Motor speed can be increased
during programming of open cycle by pushing and holding down the Bt/SET button). The
closing cycle of programming will automatically run at fast speed.
Control card will beep to confirm end of run time setup.
NOTE: If gate opens first, dipswitch number 2 is wrongly selected.
2 – Auto close (Default 15 seconds) (Infra red beams must be fitted if auto close is activated).
Switch Dipswitch 1 and 3 ON.
Press & hold Bt/SET button
PCB will Beep (1 Beep = 1 Sec)
Release Bt/SET button at required auto close time.
Switch Dipswitch 1 and 3 OFF.
Switch Dipswitch 3 back ON to activate the auto close.
3 – Pedestrian Opening (Default 1 meter / 4 seconds auto close)
Switch Dipswitch 1 and 4 ON.
Gate should be in closed position.
Press & Release Bt/SET Button.
Gate will open.
Press & release Bt/SET button to stop gate at required pedestrian opening distance.
Press & Hold Bt/SET button to program auto close time required.
Control card will Beep (1 Beep = 1 Sec)
Release Bt/SET button at required pedestrian auto close time.
Gate will close again.
Switch Dipswitch 1 and 4 OFF.
To reset factory default, push and release Bt Lrn or Pd Lrn, then press and hold Bt/SET for
approximately 5 seconds, the PCB will give 2 short beeps as acknowledgement.