7.3

Resetting the control (Reset all)

M2.xx control
The first action should always be to check and if necessary correct the machine type
setting.
All user settings will be overwritten with factory settings and must therefore be checked
afterwards, or set up again!
After resetting the machine control to the factory settings, it is essential that the machine
type used is checked and reset if necessary.
Operating
element
+
099-005224-EW501
08.11.2011
Action
Result
Switch off the welding machine.
1 x
Press and hold both buttons.
t1
t2
Switch on the welding machine, "rES" is shown briefly on the display.
1 x
NOTE
Rectifying faults
Resetting the control (Reset all)