Section Four; Removing Glass Panel - Infinity 660 PC Owner's Manual

Infinity 660 pc gas fire owner manual
Table of Contents

Advertisement

660 PC
Users Instructions
SECTIONTHREE

REMOVING GLASS PANEL

Remove the five 7mm nuts holding the front glass panel retaining bracket and slide the bracket
clear of the studs.
Lift the glass panel out of the bottom retaining bracket.
Before refitting the glass panel, loosen the side clamps retaining the side glass panels.
Fit the front glass panel within the bottom retaining bracket, position the glass panel central with
the outer side edges of the panel running flush with the two side glass panels.
Slide the top glass front retaining bracket over the five fixing studs and fit and tighten the 7mm
nuts, making sure again that the glass panel is flush and central.
Final tighten the four 7mm nuts retaining the LH and RH glass panels.

SECTION FOUR

Important: Black Glass back panel needs to be fitted before fuel bed is laid.
Ensure 3 tabs at back of tray are pushed down slightly.
Remove the 2 glass liner brackets(fixed with 2 screws and washers) the brackets are located on
the top ceramic.
Place glass at the back of the fire, ensure the textured side of the glass is facing the back of the
fire, and also that the glass is above the 3 tabs.
Bend the 3 tabs up to support the glass, and then bend the inner part of the tabs up further so it
stops the glass falling forward.
Re-fit glass retaining brackets and position so they are pushed against the glass back panel then
tighten screws
Before you clean any part of the appliance ensures that the appliance is turned off and cold.
Use only the fuel bed components provided and no additional parts must added.
Incorrect positioning of the fuel bed components could result in the staining of the glass panel.
Important: - Refer to the 'Health & Safety Notice located on page 3 of this booklet before
cleaning or replacing any refractory material.
The fuel bed components are delicate and they should be handled with great care.
The loose parts and moulded shapes may be removed for cleaning. They can be brushed very
gently with a soft brush to remove dust or any deposits.
A vacuum cleaner may only be used after the loose components and moulded shapes have been
removed.
Please make sure no loose shapes are placed directly on top of the pilot head. (Please see
figure below).
CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A
DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED.
Cleaning Continued
Fuel Bed Cleaning and Layout
9
LT6159 issue 7(06/13)