Gas Connection - Baumatic BHG400SS Instruction Manual

38cm single burner gas hob 38cm two burner gas hob
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
Gas connection (Fig. 8)
The connection to a gas tank or gas line must be made
by a qualified person in conformity to current updated
gas safety and building standards after making
sure that the cook top is prepared for the type of gas
GB
available. If not, see: "Adapting to different types of gas".
Also check that the feed pressure falls within the values
shown in the table: "User characteristics".
Fig. 8
Metal rigid/semi-rigid hook-ups
Make the hook-up with metal fittings and pipes (even
flexible hoses) so as not to stress the components inside
the cook top.
Note: - After installation, use soapy water to check the
perfect seal of the entire connection system.
Important note: make the connection using only metal
fittings and pipes (flexible, continuous-wall steel hoses
or rigid copper or steel tubing) and in such a way that its
entire length can be inspected.
Electrical connection (Fig. 9)
The installer must be qualified and is responsible for
correct electrical connections and following safety
standards.
Prior to carrying out the electrical connection, please
ensure that:
• The supply voltage marked on the rating plate
corresponds with your mains supply.
• that the appliance is fitted with an efficient earth
connection, following the standards and law
provisions in force.
The earth connectionis compulsory in terms of the
law.
Should there be no cable and/or plug on the equipment,
use suitable absorption material for the working
temperature as well, as indicated on the matrix
plate. Under no circumstance must the cable reach a
temperature above 50°C of the ambient temperature.
If connecting directly to the mains power supply, fit a
multi-pole switch of a suitable size for the rated capacity
with a clearance distance which completely disconnects
the power line under overvoltage category III conditions,
consistently with the rules of installation (the yellow/
green earth wire must not be interrupted). The plug or
omnipolar switch must be easily reached on the installed
equipment.
Fig. 9
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bhg420ss

Table of Contents