Operation - ESAB LKA 180 Instruction Manual

Hide thumbs Also See for LKA 180:
Table of Contents

Advertisement

GB
NOTE!
If the rollers slip or wire feed is unsatisfactory in any other way it may be necessary
to adjust the tension. This can be done using the tensioning screw on the pressure
arm.
WARNING!
Rotating parts can cause injury, take great care.
6

OPERATION

General safety regulations for the handling of the equipment can be found on
page 3. Read through before you start using the equipment!
S
Connect the return cable (E) to the work piece.
S
When welding with solid wire, open the gas valve (A)
and adjust the gas flow with the reduction valve (B).
The flow should be between 8−12 l/min.
S
Switch on the power source using the knob (L).
The white indicator lamp (K) should light up.
S
Press the trigger (D) on the welding torch until wire
is fed out of the contact tip (F).
S
Select suitable welding settings using the
woltage selector knob (L) and the wire feed
knod (H) as indicated by the table on page 9.
S
Start welding and adjust the settings if necessary.
S
Indication lamp (J) light up if the Power source
becomes to hot.
bc05d18e
− 7 −
bc05d005

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lka 240

Table of Contents