When All Hookups Are Complete - Electrolux 30" Service Manual

Electric freestanding ranges
Hide thumbs Also See for 30":
Table of Contents

Advertisement

Convection (some models)–When the oven is set
to CONV. BAKE/ROAST at 350°F (177°C), both
elements cycle on and off alternately and the
convection fan will turn. The convection fan will stop
turning when the oven door is opened during
convection baking or roasting.

When All Hookups are Complete

Make sure all controls are left in the OFF position.
Model and Serial Number Location
The serial plate is located on the oven front frame
behind the large oven door.
When ordering parts for or making inquiries about
your range, always be sure to include the model and
serial numbers and a lot number or letter from the
serial plate on your range.
Before You Call for Service
Read the Avoid Service Checklist and operating
instructions in your Owner's Guide. It may save you
time and expense. The list includes common
occurrences that are not the result of defective
workmanship or materials in this appliance.
Refer to the warranty and service information in your
Owner's Guide for our phone number and address.
Please call or write if you have inquiries about your
range product and/or need to order parts.
Important Safety Warning
To reduce the risk of tipping of the range, the range
must be secured to the floor by properly installed
anti-tip brackets and screws packed with the range.
Those parts are located in a plastic bag in the oven.
Failure to install the anti-tip brackets will allow the
range to tip over if excessive weight is placed on an
open door or if a child climbs upon it. Serious injury
might result from spilled hot liquids or from the
range itself.
Follow the instructions below to install the anti-tip
brackets.
If range is ever moved to a different location, the
anti-tip brackets must also be moved and installed
with the range. To check for proper installation, see
step 5.
Tools Required:
Adjustable wrench or channel lock pliers
5/16" Nutdriver or Flat Head Screwdriver
• Electric Drill & 1/8" Diameter Drill Bit (MasonryDrill
Bit if installing in concrete)
Anti-Tip Brackets Installation Instructions
Brackets attach to the floor at the back of the range
to hold both rear leg levelers. When fastening to the
floor, be sure that screws do not penetrate electrical
wiring or plumbing. The screws provided will work in
either wood or concrete.
Anti-Tip
Bracket
¾"
(1.9 cm)
1. Unfold paper template and place it flat on the
floor with the back and side edges positioned
exactly where the back and sides of range will
be located when installed. (Use the diagram in
figure 10 to locate brackets if template is not
available.)
2. Mark on the floor the location of the 4 mounting
holes (2 holes per bracket) shown on the
template. For easier installation, 3/16" (4.8 mm)
diameter pilot holes ½" (1.3 cm) deep can be
drilled into the floor.
29
Anti-Tip
Bracket
(1.9 cm)
1/2"
(1.3 cm)
Sides of
range
Figure 10
Slide
Back
¾"

Advertisement

Table of Contents
loading

This manual is also suitable for:

40"

Table of Contents