wiring between the main terminal block of the range
and the switch is open. If the meter reads line to
neutral voltage (around 120 VAC) go to step 3.
3. With the switch turned on to the high position mea-
sure the voltage drop between terminals H1 and H2.
If the meter reads zero the switch is defective. If the
meter reads line to neutral voltage the switch is good.
Go to step 4.
4. Raise the top and locate the two terminals on the
element with the wires from H1 and H2. Measure
the voltage drop between the two terminals. If the
meter reads zero, the wires between the switch and
the element are open. If the meter reads line to
neutral (120 VAC) the element is defective.

Element does not cycle:

If the element does not cycle when the switch is set in a
position other than high the switch is defective.
Indicator light does not glow:
If the indicator light does not glow when the switch is
turned on, remove the back panel of the backguard, turn
the switch on, and measure the voltage drop between
terminals H1 and neutral. If the meter reads zero the
switch is defective. If the meter reads line to neutral
voltage (around 120 VAC) the light or the wiring to the
light is defective.
Indicator light glows full brilliance with the warm
and serve switch turned off:
If indicator light glows full brilliance with the warm and
serve switch off, the switch is defective.