FINIShING

Combustible Finishing Material : Materials
made of or surfaced with wood, compressed paper,
plant fibers, plastics or any material capable of
igniting and burning, whether flame proofed or not,
plastered or unplastered (this includes drywall).
Noncombustible Finishing Material : Mate-
rials which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick,
tile, concrete, slate, glass or plasters or combina-
tions thereof, or have a fire rating of zero.
WARNING: Louvers on this
heater cannot, in any way, be
covered as it may create a fire
hazard.
FINISHING CHECKLIST
• Power supply service must be completed prior
to finishing to avoid reconstruction.
• Louvers and air openings cannot be covered in
any circumstances.
Note: The heater is a zero clearance fireplace and
may be finished with combustible or noncombus-
tible finishing materials.
When using paint or lacquer to finish the mantel, they
must be heat resistant to prevent discoloration.

SPECIFICATIONS

Power Supply: 10V; 15-Amp Grounded Plug
Frequency:
60 Hz
BTU Output:
5000 BTU
Heater Power: 1500 W
Net Weight:
44 lbs
119719-01A
Controls (see Figure 4) are located behind the
top louver panel and can be accessed by pulling
louver panel from the top, forward and down.
1. Plug in your electric fireplace.
2. Main ON/OFF power Switch and LED:
This switch is located on the far left side
opposite the control panel. The power LED
will light up when the unit is on (see Figure
4). When unit is on, the default settings for
the fireplace is low background lighting
and high ember bed and flame and the
heater is off.
3. Temperature Control Button and LED:
This button is located to the right of the
Remote Control Receiver (see Figure 4). The
LED is located to the right of the Flame But-
ton. Push button to cycle through settings.
When this button is pushed the LED will
come on. When heater is on heat will emit
through vents located in the middle of the
top louver panel.
The heater has a built-in thermostat so
it will shut off automatically once the set
temperature is reached. It will also turn
on automatically if the room temperature
drops below the set temperature.
Note: When the heater is turned on for the
first time, it may release a slight, harmless
odor. This odor is a normal occurrence caused
by the initial heating of the internal heating
elements and should not occur again after
initial burn off. (This odor may occur again
if dust or debris has been trapped.)
4. Flame Control Button: This button is
located to the right of the Temperature
Button (see Figure 5). After power is on,
push the Flame Control Button to adjust
flame and ember bed brightness. Press and
release the Flame Control Button to cycle
through settings.
ON/OFF
Power Button
Temperature
Figure 4 - Controls For Electric Fireplace
www.desatech.com
OPERATING
INSTRUCTIONS
Flame Control Power
Receiver
FL
Heater
7