7 Installation
NOTICE
The water pressure indicated on the manometer will vary
depending on the water temperature (higher pressure at
higher water temperature).
However, at all times water pressure shall remain above
1 bar to avoid air entering the circuit.
7.5.3

To fill the domestic hot water tank

For installation instructions, see the installation manual of the
domestic hot water tank.
7.5.4

To insulate the water piping

The piping in the complete water circuit must be insulated to prevent
condensation during cooling operation and reduction of the heating
and cooling capacity.
If the temperature is higher than 30°C and the humidity is higher
than RH 80%, the thickness of the sealing materials should be at
least 20 mm to prevent condensation on the surface of the sealing.
7.6

Connecting the electrical wiring

DANGER: RISK OF ELECTROCUTION
INFORMATION
More information about the legend and the location of the
wiring diagram of the unit can be found in "15.6 Wiring
diagram" on page 84.
WARNING
Always use multicore cable for power supply cables.
7.6.1

About electrical compliance

Only for ERLQ006CAV3+ERLQ008CAV3
Equipment
complying
with
International Technical Standard setting the limits for harmonic
currents produced by equipment connected to public low-voltage
systems with input current >16 A and ≤75 A per phase.).
Only for indoor units
See "7.6.5 To connect the backup heater power supply" on
page 38.
7.6.2
To connect the electrical wiring on the
outdoor unit
1 Remove the 2 switch box cover screws.
2 Remove the switch box cover.
2x
Installer reference guide
36
EN/IEC
61000‑3‑12
(European/
1
1
3 Strip insulation (20 mm) from the wires.
a
a Strip wire end to this point
Excessive strip length may cause electrical shock or
leakage.
4 Open the wire clamp.
5 Connect the interconnection cable and power supply as follows:
3x
6 Install the switch box cover.
▪ If stranded conductor wires are being used, install a round crimp-
style terminal on the tip. Place the round crimp-style terminal on
the wire up to the covered part and fasten the terminal with the
appropriate tool.
b
a
a Stranded conductor wire
b Round crimp-stryle terminal
▪ Use the following methods for installing wires:
Wire type
Single core wire
A
a Curled single core wire
b Screw
c Flat washer
Stranded conductor
wire with round crimp-
style terminal
a Terminal
b Screw
c Flat washer
b
1 2 3
Installation method
c b
AA´
c
a
a
c b
a
b
c
B
B
a
ERLQ004~008CAV3 + EHBH/X04+08CA
Daikin Altherma - Low Temperature Split
4P313774-1C – 2012.11