temperature settings are shown in the form of LED's. The illuminated LED indicates the temperature setting,
with COLD on the left and COLDEST on the right. The temperature LED turns off after 10 seconds. Quickly
press and release any button to display the temperature setting.
Start-Up Instructions – Auto Mode
When the AUTO mode is selected, the operating control automatically selects the power source using the following
priority scheme:
When 120 volts AC is available to the refrigerator, the AUTO LED and the AC LED will illuminate,
indicating the refrigerator is operating on AC electric. After 10 seconds, the AC LED will turn off and only
the AUTO LED will remain illuminated. Press and quickly release any button to display the operating
mode.
If 120 volts AC is not available, the refrigerator will switch to the gas operation. The AUTO LED and the
LP GAS LED will illuminate. After 10 seconds, the LP GAS LED will turn off and only the AUTO LED will
remain illuminated. Press and quickly release any button to display the operating mode.
During operation in the AUTO mode, when a higher priority power source becomes available, the operating
controls will cease using the current power source and will switch to the higher priority source. For example,
if AC electric becomes available while the refrigerator is operating in the AUTO LP GAS mode, the refrigerator
will switch to AUTO AC operation.
If an operating mode is not functional, its corresponding LED will flash and refrigerator will attempt to
operate in a lower power priority source. If a lower power priority source is not available, the LED will
continue to flash, and the refrigerator will cease operation until the energy source is corrected. Refer to the
"Diagnostic" section of the Dometic Refrigerators Operator's Guide in your owner's manual packet.
Start-Up Instructions – Manual Mode
To operate the MANUAL mode, press and hold the MODE button until the AUTO LED disappears and the
desired operating mode is displayed. If the power source is interrupted while operating in the MANUAL
mode, the AUTO LED disappears and the desired operating mode is illuminated. Unlike AUTO mode, the
operating mode LED remains illuminated until an alternate mode is selected. If the energy source is
interrupted while in the MANUAL mode, the corresponding LED flashes, and the refrigerator ceases operation
until an alternative energy source is selected or the problem is corrected. Refer to the "Diagnostics" section
of the Dometic Operator's Guide in your blue binder for corrective actions.
AUTO and MANUAL Modes – Gas Operation Only
If the gas does not ignite within 30 seconds, which may occur on initial start-up, the refrigerator's gas valve
will automatically close and the operating controls will select an alternate power source (AUTO Mode) or
revert to a stand-by mode in which the LP GAS LED flashes. The LED continues to flash until the refrigerator
is turned OFF and then ON. If the gas does not ignite after several attempts, check the input gas supply, or
consult with your dealer or a Dometic authorized service center. A different mode of operation may be
selected by pressing and holding the MODE button. The refrigerator will not switch to the new operating
mode until the MODE button is released.

Backup Operating System ("BOS")

Your refrigerator features a Backup Operating System which keeps the refrigerator cool in the event of a
failure of the refrigerator's operating controls. If a failure occurs, the TEMP SET LED flashes and refrigerator
switches to the BOS mode. This mode provides refrigeration until the refrigerator is serviced. The fresh food