Operation - MULTIQUIP DA7000SSA2GH Operation And Parts Manual

Table of Contents

Advertisement

Before Starting the Engine
CAUTION
The engine's exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating.
Direct exhaust away from nearby personnel.
NOTICE
The DA7000SSA2/SSA2GH generator is equipped with
a GFCI sensing module. The purpose of this module is
to sense a ground fault during operation of the generator
and open the main breaker once the ground fault has
been detected.
Multiquip recommends that the GFCI sensing module
be tested before each use of the generator. Refer to the
maintenance section of this manual for testing of the
GFCI module.
1. Open the cabinet door and turn the fuel cock lever
(Figure 18) to the "ON" position.
Figure 18. Fuel Cock Lever (ON)
2. NEVER operate the generator with the doors open
(Figure 19). Operation with the doors open may cause
insufficient cooling of the unit, and engine damage may
result. Close the doors for normal operation.
Figure 19. Generator Doors
DA7000SSA2/SSA2GH GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 (03/26/15) — PAGE 29
3. NEVER start the engine with the main circuit breaker
in the ON position. Always place circuit breaker (Figure 20)
in the OFF position before starting.
Figure 20. Main Circuit Breaker (OFF)
4. NEVER start the engine with the auxiliary circuit
breakers in the ON position. Always place circuit
breakers (Figure 21) in the OFF position before starting
the engine.
Figure 21. Auxiliary Circuit Breakers (OFF)
Starting the Engine
1. Insert the key into the starter switch (Figure 22) and
turn it to the "RUN" position. Check to see that the oil
pressure and charge Lights on the "Warning Lamp Unit
Display" are lit. If either light is not lit, check the system
and wiring (refer to the Engine Operation Manual).
Figure 22. Starter Switch
2. Turn the ignition key to the HEAT position. When the
preheat light goes off, turn the key to the START
position to start the engine. As soon as the engine
starts, release the key. The key will automatically return
to the RUN position.
3. In cold weather conditions, it may be required to extend
the duration of the HEAT position for proper starting.