CLEANING THE RADIATOR
The engine may overheat if the radiator fins become
overloaded with dust or debris. Periodically clean the
radiator fins with compressed air. Cleaning inside the
machine is dangerous, so clean only with the engine turned
off and the negative battery terminal disconnected.
AIR CLEANER
Periodic cleaning/replacement is necessary. Inspect it in
accordance with the KUBOTA Engine Owner's Manual.
Fan Belt Tension
A slack fan belt may contribute to overheating, or to
insufficient charging of the battery. Inspect the fan belt
for damage and wear and adjust it in accordance with the
Kubota Engine Owner's Manual.
The fan belt tension is proper if the fan belt bends 10 to 15
mm (Figure 16) when depressed with the thumb as shown
below.
Figure 16. Fan Belt Tension
CAUTION
NEVER place hands near the belts or fan
while the generator set is running.
BATTERY
This unit is of negative ground DO NOT connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are
not properly maintained. Add only distilled water when
replenishment is necessary.
DA7000SSA2/SSA2GH GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 (03/26/15) — PAGE 27
INSPECTION/SETUP
DO NOT over fill. Check to see whether the battery
cables are loose. Poor contact may result in poor starting
or malfunctions. Always keep the terminals firmly
tightened. Coating the terminals with an approved battery
terminal treatment compound. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity
of the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
Battery Cable Installation
ALWAYS be sure the battery cables (Figure 17) are
properly connected to the battery terminals as shown below.
The red cable is connected to the positive terminal of the
battery, and the black cable is connected to the negative
terminal of the battery.
CAUTION
ALWAYS disconnect the negative terminal FIRST and
reconnect negative terminal LAST.
POSITIVE
Figure 17. Battery Connections
When connecting battery do the following:
1. NEVER connect the battery cables to the battery
terminals when the Ignition Switch is in the START
position. ALWAYS make sure that the Ignition Switch
is in the OFF position when connecting the battery.
NEGATIVE