CVS4 Command Reference (Cont'd)
Control Settings (HDS4.2 Version)
Note: This command exists for backwards compatibility with the HDS4.2, use the "XS" version of
this command in new designs.
X settings
X ?
X
Response String:
=Xsettings
Where 'settings' is a bitmapped parameter:
Decimal Value
Bit Position
Name
Factory Settings:
AS
- 0=Master / Slave mode.
KB
- 0=Front Panel Active.
IR
- 0=IR remote Active.
0
- Reserved, always set to 0.
Note: For backward compatibility with the HDS4.2, there is no space after the command in the
response string.

Extended Control Settings

In the Asynchronous mode of operation, the CVS4 will transmit state changes as they occur.
This command allows individual control over which state changes will be sent.
This CVS4 allows control over the following states:
Power State changes (On / Off condition).
Selection changes (input / output mapping changes).
Front Panel modes and intensity changes
Front Panel Button Presses.
IR codes received.
New IR codes learned.
Control Settings changes.
Each of the above states can be selectively set to asynchronously transmit their state changes,
or run in the Master / Slave mode. If asynchronous transmit has been disabled for one of the
options, then that option will revert to the Master / Slave mode.
The 'AS' in the "Control Settings" command must be set to '1' to allow any Asynchronous
Set the control bits to 'settings'
Query for current settings.
Query for current settings.
+128 +64 +32 +16
7
6
5
4
0
0
0
0
0
0
0
0
1=Asynchronous Mode.
1=Front Panel Disabled.
1=IR remote Disabled.
+8
+4
+2
+1
3
2
1
0
0
IR
FP
AS
0
0
0
0