X & Y "0" Calibration Adjustment
This procedure is used for adjusting the X and Y "0" point of the printer to be equal to the Color
Byte software "0" point.
Tools Required
1/16" hex head wrench
3/32" hex head wrench
Time Required
Approximately 20 minutes
1.
Make sure the print engine power is ON (
2.
Load a piece of 8.5" x 11" (or A4) paper or a white substrate of similar size. Use the edge
guides to align it on the left edge of the table.
3.
Open the Color Byte Rip Pro Queue. Select the Color Only queue.
4.
Be sure the table is at Print Home. Go to Devices>Print Test Page. Select the First Dot file and
click OK.
5.
After the file has been imported, click Print.
DCS_Direct_Jet_1024UVHS_Maintenance_Troubleshooting_Guide_1.2.docx
the green LED is on solid).
Go to table of contents
19 |
P a g e