ASSIGN screen

Allows you configure recall safe and mute safe settings, DCA group assignments, signals sent to the SUB bus, etc. for each
channel.
1
Recall Safe button
Turns Recall Safe on and off for the corresponding channel.
You can display the RECALL SAFE screen by touching the jump button in the right corner of the Recall Safe button.
(page
20)
2
Mute Safe button
You can temporarily exclude certain channels from a mute group.
If you mute a mute group, any channels in that group that have mute safe enabled will not be muted.
3
ST button
Turns the channel's assignment to the stereo channel on and off.
4
SUB button
Determines whether the channel's signal is sent (on) or not sent (off) to the SUB bus.
5
SUB level slider
Determines the amount of signal sent from the selected channel to the SUB bus.
6
DCA buttons
Turns the channel's assignment to each DCA group (1–8) on and off.
You can assign a channel to multiple DCA groups if desired.