6.7 CONTROL PANEL
ELECTRICAL SERVICE ACCESS
The control panel assembly is mounted onto the front
of the unit. It houses all of the controls and indicators which
are used to operate the Steam Tech Plus. In order to service
any of the control panel electrical componentry, the control
panel assembly must be removed from the front of the unit.
CAUTION: Be sure to disconnect 120 volt power supply from
the unit and turn off the main gas supply before servicing any
electrical componentry.
Procedure:
1. Remove the 4 screws that fasten the control panel
assembly onto the front of the unit.
2. Gently move the control panel assembly out
ITEM
QTY.
DESCRIPTION
I
1
Buzzer
2
1
"Clean Generator" Indicator Light (round neon, red)
3
1
"Constant Steam" Button
4
1
"Constant Steam" Indicator Light (round neon, green)
5
1
Control Panel Housing Assembly
6
1
Control Panel Light Mounting Bracket
7
1
"Hold" Indicator Light (round neon, amber)
8
1
"Mode Select" Switch Assembly
9
1
"Power On" Indicator Light
10
1
"Power On" Indicator Light Tinnerman Retainer Clip
11
1
Power Switch
12
1
"Ready* Indicator Light (rectangular neon, green)
13
3
Round Indicator Light Retainer Clip
14
1
"Steam Demand" Indicator Light (rectangular neon, red)
15
1
"Steam On" Indicator Light (rectangular neon, green)
16
1
Terminal Block
17
1
Timer
18
1
Timer Knob
19
1
Timer Mounting Nut
20
4
1/4-20 Hex Nut, zinc plated
21
2
6-32 Nut with nylon insert, zinc plated
22
2
6-32 Slotted Pan Head Machine Screw, zinc plated, 1/2" long
23
4
8-32 Nut with nylon insert, zinc plated
MARKET FORGE INDUSTR IES
35 GARVEY STREET EVERETT, MA 02140
TEL-: 617 387 4100 TELEX: 34-9414
FAX: 617 387 4456 OUTSIDE MA 800 227 2659
Table 6.3 - Control Panel Assembly Parts List
,
.
INC
away from the unit.
NOTE: Only move the control panel assembly out as far as
is necessary to access the rear of the assembly. PULLI N G
THE CONTROL PANEL OUT TOO FAR CAN CAUSE
DAMAGE BY PUTTING UNNECESSARY STRAIN ON
WIRES AND CONNECTIONS!
3. Separate the control panel housing and indicator light
mounting bracket by removing the 4 nuts which hold them
together. Be careful not to lose the 1/4-20 nuts which are
used as spacers, (I -per stud). This will allow total access
to all controls and indicators for service, repair, or
replacement. See Figure 6.3 on page 6.11.

6.8 DOOR ADJUSTMENT

6.10
PART NO.
El 0-6682
E08-6530
E08-6526
E08-6529
E91-5743
E91-5688
E08-6531
E08-6525
E08-6523
E08-6523
E08-6524
E08-6527
E08-6527
E08-6528
E08-6527
E08-6518
El 0-6291
E08-3826
El 0-6291
E08-3844
E08-3838
E08-3484
E08-3839

Advertisement