6.5 CLEANING THE STEAM
VENTILATION DUCTWORK
The Steam Tech Plus steam ventilation ductwork
system is made up of a series of horizontal and vertical
ducts. This series of ductwork must be cleaned
periodically, in order to maintain cleanliness.
Frequency will vary according to use. The recom-
mended procedure for cleaning of the steam ventilation
ductwork is contained in this section.
NOTE: In order to perform this procedure, you
must gain access to the rear of the unit.
Procedure:
1. Turn off the Main gas supply and disconnect the
gas service connection.
2. Disconnect the 120v power supply.
3. Slide the unit out, away from the wall. (You may
need to disconnect the water inlet line.)
4. Remove the 11 screws which hold the louvered
vent access hatch onto the rear panel of the
unit. (Refer to Figure 6.1 on page 6.2.)
5. Using detergent and a damp cloth, wipe clean the
inside of both the upper and lower horizontal
intake ducts, located just above the cooking
compartments. The very front of these ducts
may be accessed more easily from the front of
the unit.
6. Using detergent and a damp cloth, wipe clean the
inside of both the vertical intake and exhaust
ducts. These ducts are mounted onto the Inside
of the rear panel of the unit.
CAUTION: When cleaning the vertical
exhaust duct, be very careful not to damage
the blower, which is located at the bottom of
this duct. Looking at the unit from the rear,
the vertical exhaust duct is the one on the
right..
,
MARKET FORGE INDUSTRIES
INC
35 GARVEY STREET EVERETT, MA 02149
TEL: 617 387 4100 TELEX: 94-94 1 4
FAX: 6 17 387 4456 OUTSIDE MA 800 227 2659
6. Maintenance
.
7. Using detergent and a damp cloth, wipe clean
the inside of the vent access hatch.
8. Reinstall vent access hatch onto rear of unit.
9. Using detergent and a damp cloth, wipe clean the
inside of the upper and lower steam vent hoods,
located on the front of the unit, just above each
of the cooking compartments.
10. Reconnect 120v power supply.
11. Reconnect the gas service connection and turn
the Main gas supply back on.
12. Slide the unit back into place.
NOTE: You may need to relevel the unit, as
described in step 5 of Section 2.1.
13. If you have disconnected the water inlet line,
reconnect it now.

6.6 ELECTRICAL BOX SERVICE ACCESS

The Steam Tech Plus electrical box is located
behind the lower front panel of the unit. Most major
electrical componentry is mounted onto the inside of
the electrical box.
CAUTION: Be sure to disconnect BOTH power
supplies from the unit before servicing any
electrical componentry.
To gain access to the electrical box, the lower
cover panel must be removed from the front of the unit.
Prior to removing this panel, the lower drip/spill trough
screen must be removed. Gripping the round handle,
slide the panel upwards until it stops, and pull it out
away from the unit. This will reveal the hinged
electrical box. Unscrew the captive screw latch, which
is located on the left side of the electrical box and
swing the electrical box open to access the electrical
componentry for service.