VISTA-50P/VISTA-50PUL Installation and Setup Guide
Partitioning
Can control 8 separate areas independently, each functioning as if it had its own separate control.
Provides a Common Lobby partition, which can be programmed to arm automatically when the last partition is
armed, and to disarm when the first partition is disarmed.
Provides a Master partition (9), used for the purpose of viewing the status of all partitions at the same time.
Scheduling
Can automate system functions, such as arming, disarming, and activation of outputs (e.g., lights).
Provides access schedules (for limiting system access to users by time).
Provides an End User Output Programming Mode, allowing the user to control outputs.
Access Control
Provides the capability to trigger a relay for two seconds by entering the user code + 0 at a keypad.
System Communication
Supports ADEMCO Contact ID; ADEMCO High Speed; ADEMCO Express; and 3+1, 4+1, and 4+2 ADEMCO and
Sescoa/Radionics Low-Speed formats.
The system is shipped defaulted for Contact ID communication. It is the only format capable of uniquely reporting all
86 zones, as well as openings and closings for all 75 users. This requires central stations to be equipped with the
685 receiver using software level 4.10 or higher to fully support all new VISTA-50P/VISTA-50PUL report codes. If
you need to update your 685 receiver, contact your distributor.
Provides an Audio Alarm Verification (AAV) option that permits voice dialog between an operator at the central
station and a person at the premises. An AAV unit, such as ADEMCO UVS, is required.
Downloading
Supports upload and download capability of program and user information.
Event Log
Provides an event log (history log) that can store up to 224 events.
Can print the event log on a serial printer using the 4100SM.
Can view the event log on an alpha keypad.
Additional Features
Provides up to 20 installer-defined, custom words that can be used for zone descriptors.
Provides a keypad macro command (macro is a series of keypad commands of up to 16 keystrokes) using the D key
by partition.
Provides cross-zone capability, which helps prevent false alarms by preventing a zone from going into alarm unless
its cross-zone is also faulted within a 5-minute period.
Contains a built-in User's Manual, which provides the end user with a brief explanation of the function of a key
when the user presses any of the function keys on the keypad for 5 seconds.
Provides trigger outputs, which may interface with Long Range Radio equipment or other devices such as keyswitch
LEDs, printer, or pager.
At least one 2-line alpha keypad (6139/6160) must be connected to the system for programming (if you are using
keypad programming), and must remain connected to the system in order to allow the primary user to program
additional user codes into the system at a later time.