Checking Pilot And Burner Flames - Valor RETROFIRE RF24IDN Installation And Owner's Manual

Direct vent fireplace insert ng, lpg
Hide thumbs Also See for RETROFIRE RF24IDN:
Table of Contents

Advertisement

7. Reinstall the window.
a. Hook the window over the top edge of the fi rebox,
and fasten the bottom two spring- loaded bolts by
pushing in and turning them 90 degrees.
Check that Window
Moves Freely After
Reinstallation
Spring Loaded
Fastening Studs (2)
IMPORTANT: To ensure a safe operation, verify that
the bolts are hooked properly to the window tabs;
then, pull out the bottom of the window and release it
to insure the springs return it.
b. Apply light hand pressure against the window
frame sides to bed-in the window seal.
c. If the Hot Glass Warning plate has been
removed from the front lower corner of the
window, reinstall it by sliding it between the
glass and the frame as indicated.
Hot Glass Plate
8. Reinstall the barrier screen.
WARNING
!
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the fi replace window
after maintenance.
Owner's Information
1/4 Turn
a. Hook the bottom of the screen to the bottom
edge of the window frame and then push the
screen against the window frame.
Convection baffl e
Top view—Hook bottom of screen to bottom of
window frame
b. Push the top of the screen against the top of the
window frame and while holding it bend the top
brackets around the window frame to secure the
screen. Check that the screen is solidly hooked
to the window frame.

Checking Pilot and Burner Flames

A
periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions—see images below.
Correct Flame Picture
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that, snow, leaves, bushes, trees, etc, do not
obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
OWNER'S
INFORMATION
Pilot Flame
Thermocouple
Probe must be
in Flame
7