Synchronize Remote Control; Check Operation; Adjust Aeration (If Necessary) - Valor RETROFIRE RF24IDN Installation And Owner's Manual

Direct vent fireplace insert ng, lpg
Hide thumbs Also See for RETROFIRE RF24IDN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Synchronize Remote Control

The receiver and the handset of the remote control
system must be initially synchronized before the fi rst
use.
1. Insert alkaline batteries in the remote control
receiver and handset. The receiver is located left of
the control valve under the burner module.
2. With a sharp object, press and hold the receiver's
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button (
) on the remote handset until you
hear two short beeps confi rming the sychronization
is set.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.

Check Operation

Turn the fi replace up and down using the remote
control to confi rm that the full range of inputs is
achieved.

Adjust Aeration (if necessary)

Light the fi re and allow to warm up for 10–15 minutes
to evaluate the fl ame picture.
with an adjustable air shutter to control primary
aeration. See fi gures below. The shutter is factory-
set at an aeration gap, which will give optimum
performance for the vast majority of installations. In
a few unusual installations, fl ame picture may be
improved by adjusting the aeration. The need for
adjustment should be determined only by operating
the appliance with the ceramic fuel effects and
window installed.
Increasing aeration will cause the fl ame to appear
more transparent and blue making the ceramic fuel
effects glow more.
Decreasing aeration will cause the fl ames to appear
more yellow or orange making the fuel effects glow less.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
28
Installation
The burner is equipped
Air Shutter Components
Air Shutter in
Open Position
Air Shutter
Air Shutter Retainer
Air Shutter in
Closed Position