RESETTING TO FACTORY DEFAULTS

!
All information in the lock will be deleted and reset to factory defaults!
1. Remove the top inside cover.
2. Press and hold Schlage button until two (2) beeps sound (10 seconds).
3. Release the Schlage button.
4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One beep will
sound and one red blink will occur with each press.
5. The Schlage button and IPB will both light green for one second and a one-second beep will be
heard. This indicates that the lock has been reset.
ÎIf IPB is not pressed 3 times within 10 seconds, two beeps with two red blinks indicate timeout
6. Replace the top inside cover.
ÎThe Magnetic Reader will revert to Track 2 after default reset. See the Schlage Utility Software User
Guide for information on how to change track.
The AD-250 may be connected to external power using a UL294 Listed Power Supply capable of
sourcing at least 250 mA @ 12 to 24 VDC.
ÎWhen powered with external power supply, the lock will always fail "As-Is" if power is lost.

EXTERNAL POWER SUPPLY

+
Polarity Required
!