Construction Access Mode; Create The Master Construction Credential - Locks With Card Readers; Add User Credentials - Locks With Card Readers; Cancel Construction Access Mode - Schlage AD-250 User Manual

Offline lock
Table of Contents

Advertisement

Construction Access Mode is used to allow access before the lock has
been programmed, and for testing purposes.
• Enabled by default.
• The lock will remain in Construction Access Mode until the mode is
cancelled as described below.
• No audits are captured while the lock is in Construction Access
Mode.
Create the Master Construction Credential - Locks with
Card Readers
!
The first card presented to a new lock automatically becomes
the Master Construction Credential!
After you have created the Master Construction Credential, you can
then use that card to add construction access mode user credentials.
ÎThe Master Construction Credential will not grant access.
It is used only to add additional access credentials.

Add User Credentials - Locks with Card Readers

1. Present the Master Construction Credential to the lock.
The Schlage button will light green.
2. Present the user credential to be added within twenty (20)
seconds. The user credential will be added to the lock database.
3. To test enrolled user credential, present the credential. The Schlage button will blink and the lock
will unlock.
ÎCredentials added using the Master Construction Credential will have normal 24/7 access.

Cancel Construction Access Mode

Do one of the following:
• Reset the lock to factory settings. See Resetting to Factory Defaults on page 6 for more
information.
• Authenticate or program the lock with the HHD. See the Schlage Utility Software User Guide for
more information.
• Create a master programming credential or create a new programming code.
!
When construction mode is cancelled, the Master Construction Credential and all other
credentials added using the Master Construction Credential will no longer function.

Locks with Keypads

In the factory default reset state, offline locks with keypads, with or without additional credentials,
have a default PIN of 13579, which can be used for installation, testing and construction access.
To test, enter default PIN. The Schlage button will blink and the lock will unlock. The default PIN is
automatically deleted when a new programming credential is created, or the lock is programmed with
the Schlage Utility Software (SUS).

CONSTRUCTION ACCESS MODE

AD-250 Offline Lock User Guide
5
TIPS
Use the same Master
Construction Credential for
all the locks in the facility.
If you present the first card
to a new lock to create
the Master Construction
Credential and the card is
not accepted, the lock has
either been programmed
or already has a Master
Construction Credential.
If the Master Construction
Credential cannot be
located, or to put the lock
back into construction
access mode, reset the
lock to factory settings.
See Resetting to Factory
Defaults on page 6 for more
information.