Control board – ATTACK DP STANDARD
Wood gasifying boiler "ATTACK DP Standard" is controlled by a boiler and flue gas
thermostat.
ATTACK DP 25-45
ATTACK DP 75-95
Description:
1. Reset - protection of the boiler against overheating (in case the temperature is higher than
110°C, the boiler is disconnected from the power net)
2. Fuse - protection of the boiler against short circuit
3. Main switch - switching on of the boiler,switching off if necessary
4. Flue gas thermostat - when the temperature of flue gas drops below the set up value, the fan
is switched off
5. Boiler thermostat - serves for setting up maximum temperature of water in the boiler (after
exceeding set up temperature the fan is switched off and the boiler works with
minimum output. After decreasing set up temperature the fan is switched on again
and the boiler works with maximum output.
6. Thermometer - indicates the temperature of outlet water from the boiler
7. Pull rod control - serves for opening and closing of fuel cut-off flap
1
2
3
4
5
6
7
1 - Reset
2 - Fuse
3 - The main switch
4 - Flue gas thermostat
5 - Boiler thermostat
6 - Thermometer