Installing and Wiring the Thermostat
Remove the base plate from the wall and drill two or three holes at the marked
3
locations: for drywall, drill 3/16" holes; for plaster, drill 7/32" holes.
Gently tap the wall anchors (included in the packaging) into the drilled holes until
4
they are flush with the wall.
Pull the wires through the base plate and position the base plate over the screw holes.
5
Attach the base plate to the wall using three 1" screws (included in the packaging).
6

Wiring the Base Plate Terminals

This section describes how to wire the base plate terminals. Use the instructions in this
section and refer to:
Table 2
Burner HVAC. A Fuel Burner typically burns fossil fuel like oil or gas and does
not have a wire used as a reversing valve.
Table 2
Pump HVAC. A Heat Pump configuration always has a wire used to control a
reversing valve.
Refer to the labels you placed on the wires when you removed the existing thermostat.
See
page
Some newer Heat Pumps use traditional Fuel Burner wiring schemes without a
Reversing Valve (RV). Therefore, you may have to use a Fuel Burner wiring
Note
scheme to control your Heat Pump. Refer to your Heat Pump manual for wiring
H
details.
You must know the type of Reversing Valve in your heat pump. Refer to your Heat
Pump manual for more information.
Table 2
and dual-stage Fuel Burner and Heat Pump applications.
Table 2 Terminal Conversion Chart
HVAC
Terminal
a
C
RH
RC
W1
b
W2
c
Y1
d
Y2
4
Beta Draft Confidential
and
Figure 1 on page 5
and
Figure 2 on page 6
1.
lists the standard HVAC terminal label required to support the single-stage
Single Stage
Dual Stage
Fuel Burner
Fuel Burner
24VAC common
24VAC common
24VAC hot
24VAC hot
24VAC hot
24VAC hot
Heat
1st stage Heat
not used
2nd stage Heat
Cool
1st stage Cool
not used
2nd stage Cool
Proliphix Internet Managed Thermostat (IMT) Installation Guide, Release 1.0
to wire the IMT base plate terminals for Fuel
to wire the IMT base plate terminals for Heat
Single Stage
Heat Pump
24VAC common
24VAC hot
24VAC hot
Auxiliary Heat
RVS O/B
1st stage
Compressor
not used
Part No. 600-03100-000, Rev. 2
Dual Stage
Heat Pump
24VAC common
24VAC hot
24VAC hot
Auxiliary Heat
RVS O/B
1st stage
Compressor
2nd stage
Compressor