  • Page 1: Access Point

    ® Brocade Mobility 650 Access Point Installation Guide Supporting software release 4.3.0.0 and later 53-1001934-02...
  • Page 2 United States government. The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
  • Page 3: Table Of Contents

    Site preparation ............1 Brocade Mobility 650 package contents ........2 External antenna model package contents .
  • Page 4 Korea ..............30 5 Waste Electrical and Electronic Equipment (WEEE) Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 5: About This Document

    The following hardware platforms are supported by this release of this guide: • Brocade Mobility 650 Access Point The following software versions are supported by this release of this guide: • Software version 4.3.0.0 and later Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 6: Document Conventions

    Contacting Brocade When contacting Brocade support, please provide the following information: • Serial number of the unit • Model number or product name • Software version Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 7: Warranty Coverage

    E-mail and telephone access Go to http://www.brocade.com/services-support/index.page for email and telephone contact information. Warranty coverage Contact Brocade Communications Systems using any of the methods listed above for information about the standard and extended warranties. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 8 Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 9: Introduction

    The Brocade Mobility 650 receives all power and transfers data through the same CAT-5 or better Ethernet cable. There is no additional power supply required. An 802.3af Ethernet switch or power injector is required.
  • Page 10: Brocade Mobility 650 Package Contents

    Brocade Mobility 650 package contents The Brocade Mobility 650 Access Point comes in four configurations, two Integrated antenna models and two external antenna models. The contents of the package differ between the integrated antenna model and the external antenna model.
  • Page 11 When operating in a Gigabit Ethernet environment CAT-5e or CAT-6 cable is required for Gigabit operation. The Brocade Mobility 650 comes in both single and dual radio versions both supporting 802.11a/b/g/n. The Brocade Mobility 650 Access Point contains runtime firmware which enables the unit to boot after either a power up or a watchdog reset.
  • Page 12 Brocade Mobility 650 package contents Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 13: Hardware Installation

    Hardware Installation Installation instructions The Brocade Mobility 650 mounts either on a wall with wide-shoulder screws or on a suspended ceiling T-bar. This unit is not designed for mounting on a desk. To prepare for installation, perform the following steps: 1.
  • Page 14: Precautions

    Precautions Before installing a Brocade Mobility 650 Access Point, verify the following: • Brocade recommends not to install the Brocade Mobility 650 in wet or dusty areas. • Verify the environment has a continuous temperature range between 0° C to 50°...
  • Page 15: Wall Mount Hardware

    In the event that the original mounting screws are lost, the following screws can be used instead: (ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping Screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping Screw. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 16: Wall Mount Procedure

    1. Orient the case on the wall by its width or length. CAUTION To ensure proper operation of the Brocade Mobility 650 access point ensure that the access point is mounted in the correct orientation with the logo facing up.
  • Page 17: Integrated Antenna Model Suspended Ceiling T-Bar Mount Instructions

    Verify the unit has power by observing that the LEDs are lit or flashing. Integrated antenna model suspended ceiling T-bar mount instructions Ceiling mount requires holding the Brocade Mobility 650 up against a T-bar of a suspended ceiling grid and twisting the case onto the T-bar. Brocade Mobility 650 Access Point Installation Guide...
  • Page 18: Suspended Ceiling Mount Procedure

    6. Push the back of the case onto the bottom of the T-bar. Rotate the case 45 degrees counter-clockwise. The clips click as they fasten to the T-bar. 8. Verify the unit has power by observing the LEDs. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 19: External Antenna Model Wall Mount Instructions

    Wall mounting requires hanging the Brocade Mobility 650 along its width or length using the pair of slots on the bottom of the unit. Brocade Mobility 650 can be mounted onto any plaster, wood, or cement wall surface using the provided wall anchors when necessary.
  • Page 20: Wall Mount Procedure

    NOTE When pre-drilling a hole the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into the wall and 6mm (0.23in.) if the provided wall anchors are being used. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 21: External Antenna Model Suspended Ceiling Tile (Plenum) Mount Instructions

    10. Verify the unit has power by observing that the LEDs are lit or flashing. External antenna model suspended ceiling tile (plenum) mount instructions Ceiling mount requires placing the Brocade Mobility 650 above a suspended ceiling and installing the provided light pipe for viewing the status lights of the unit. NOTE Notes or warnings about suspended ceiling mounts apply to all installations where the unit is placed on suspended ceiling tile.
  • Page 22: Suspended Ceiling Mount Hardware

    5. Push the light pipe through the tile at the mark and remove the light pipe. If necessary, use a drill to make a hole in the tile. 6. Attach appropriate antennas to the connectors. Snap the clips of the light pipe into the bottom of the case. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 23: Brocade Mobility 650 External Antenna Model Antenna Options

    Brocade Mobility 650 external antenna model antenna options Brocade supports two antenna suites for Brocade Mobility 650 External Antenna models. One antenna suite supporting the 2.4 GHz band and another antenna suite supporting the 5 GHz band. Select an antenna model best suited to the intended operational environment of your access point.
  • Page 24: Led Indicators

    ML-2452-PNA5-01R Panel Antenna ML-2452-PTA3M3-036 Omni-Directional Antenna For detailed specifications on the antennas available to the Mobility 650, refer to the Enterprise Wireless LAN Antenna Specification Guide available at http://www.brocade.com/support/. LED indicators Both the Integrated Antenna model and the External Antenna model have LED activity indicators on the front of the case for use with wall mount.
  • Page 25: Specifications

    Chapter Specifications Brocade Mobility 650 external antenna model electrical characteristics A Brocade Mobility 650 external antenna model access point has the following electrical characteristics: Operating current & voltage 180ma- 270ma @ 48VDC Brocade Mobility 650 external antenna model physical characteristics...
  • Page 26: Brocade Mobility 650 Integrated Antenna Model Electrical Characteristics

    Brocade Mobility 650 integrated antenna model electrical characteristics Brocade Mobility 650 integrated antenna model electrical characteristics A Brocade Mobility 650 Integrated model access point has the following electrical characteristics: Operating Current & 180ma- 270ma @ 48VDC voltage Brocade Mobility 650 integrated antenna model...
  • Page 27: Radio Characteristics

    Radio characteristics Radio characteristics The Brocade Mobility 650 access points have the following radio characteristics: Operating channels All channels from 4920 MHz to 5825 MHz except channel 52 -64 Channels 1-13 (2412-2472 MHz) Channel 14 (2484 MHz) Japan only Actual operating frequencies depend on regulatory approval for the country of use.
  • Page 28: Console Cable

    A console cable (pictured below) is used to connect the Brocade Brocade Mobility 650 access point ’s serial port to an RS-232 (DB-9) serial port on a separate computer. The pinout for the RJ-45 to DB9 cable is shown in the following table. RJ-45 Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 29: Regulatory Compliance

    United States, Canada, Japan, China, S. Korea, Australia, and Europe. Please refer to the Symbol Declaration of Conformity (DoC) for details of other country markings. This is available at http://www2.symbol.com/doc/. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 30: Country Selection - Note For Ap & Wireless Controller

    The range of channels is limited by firmware. 2.4 GHz only The available channels for 802.11 b/g operation in the US are Channels 1 to 11. The range of channels is limited by firmware. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 31: Health And Safety Recommendations

    • Should use the ear furthest from the pacemaker to minimize the potential for interference. • If you have any reason to suspect that interference is taking place, turn OFF your device. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 32: Rf Exposure Guidelines

    To comply with EU RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 33: Us And Canada

    • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 34: Radio Frequency Interference Requirements - Canada

    (2) this device must accept any interference received, including interference that may cause undesired operation. Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada technical specifications were met. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 35: Ce Marking And European Economic Area (Eea)

    Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 36: Korea Warning Statement For Class B Ite

    é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.” Para maiores informações sobre ANATEL consulte o site: http://www.anatel.gov.br Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 37: Chile

    The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 38: Korea

    2. “This radio equipment cannot provide a service relevant to the human life safety, as it can be crossed” through the user manual etc. 당해 무선설비 는전파혼 신 가능성이 있으므로 인명안전과 관련된 서비스는 할 수 없습니다 Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...
  • Page 39: Waste Electrical And Electronic Equipment (Weee)

    Chapter Waste Electrical and Electronic Equipment (WEEE) For information on WEEE, please go to: http://www.brocade.com/sites/dotcom/company/ corporate-responsibility/corporate-citizenship/product-recycling/ weee.page. Brocade Mobility 650 Access Point Installation Guide 53-1001934-02...