Montigo H34DF Installation & Maintenance Manual page 23

Indoor residential
Table of Contents

Advertisement

Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Side wall clearances are 3". Combustible surrounds may be installed with
3" clearance to the side of the fireplace as shown in Figure 26 or 26a.
Drywall/
Sheetrock
Combustible Header
Figure 26. H34DF* and HL34DF*Combustible surrounds.
Drywall/ Sheetrock
Combustible Header
Nailing Flange
Figure 26a. HC34DF* Combustible surrounds.
WARNING
Do not place any materials or objects on top of the
valve blind. Doing so could result in failure of door
relief system or heat dissipation.
XG0146 - 150204
Installation
6"
45°
3"
3"
6"
45°
3"
H*34DF Indoor Gas Fireplace
Page 23