7. IN LINE

There are two types for IN LINE; CATEGORY5A and ARCNET.
7-1. ARCNET
1 ARCNET connection diagram
The maximum ARCNET cable length and the maximum connection unit will be varied by the in-line
communication speed as shown below list.
[ARCNET cable wiring]
QT2100-1
R/J
Note: When the cluster has more than 8 QT-2100 terminals, all printer should be local printer. When
the cluster has less than or equal to 8 QT-2100 terminals, remote printer is allowable.
ARCNET communication speed
(Baud rate)
312.5 K bps
156.25 K bps
2 In line cable, Connector, and Terminater
ARCNET cable
Code No.
1904 4023
ARCNET connector(ECR side)
Code No.
3540 3924
Terminater
Code No.
2600 2516
QT2100-2
QT2100-3
R/J
Parts name
In-line cable
Parts name
In-line connector kit
Parts name
Carbon film resistor
— 33 —
In-line
QT2100-4
R/J
R/J
Maximum
connection unit
20
32
Specification
IPEV-SLA0.5x1P
Specification
XLP-KIT-2
Specification
R-25-100-J
A
Total Length :
QT2100-32
R/J
Maximum
cable length A (m)
430
890