Connecting the Power Exhaust Lead to the Fireplace

The power exhaust is wired to the 120v line exiting the exhaust blower rheostat. Connect a minimum
12 gauge sheathed three-wire electrical line to the power exhaust lead (included loose with fireplace)
and connect it to the molex connector on the fireplace – see illustration below. This wire is routed to
the power exhaust assembly (see "Wiring the Power Exhaust Assembly" for details)..
HINT: Keep the cover plates disconnected until all wiring to the fireplace is attached. You may also
wish to leave the romex clamps loose until the cover plates are ready to be attached.
Power Exhaust Lead
Power Exhaust
Power Out
© Travis Industries
Installation
(for qualified installers only)
Inner Cover Plate
Romex Clamp
4150126
Grommet
(remove to install wire)
1/4" Nutdriver
Outer Cover Plate