Gas Inlet Location

Gas inlet is determined by fireplace configuration and how the fireplace was ordered. Refer to the
dimensions pages for the configuration being used to determine what options are available (pages 7
through 12). When ordering the fireplace, the gas inlet is either from the side (left or right) or from the
base (left or right).
Gas inlet dimensions are shown below. Make sure to refer to the end style being used.
Type of Fireplace
1-Sided
See Through
Pier
Full Bay
Island
Gas Inlet – Steel End
The gas inlet is on the side (not available from the base).
Gas Inlet – Glass End
The gas inlet is on the side or the base. NOTE: The gas inlet on the base is only available in one
location. When looking from the side, the gas inlet from the base will always be on the left.
Side Inlet
1"
(25mm)
3.125" (80mm)
© Travis Industries
Installation
Type of Ends
Two Steel Ends
Two Steel Ends
One Steel, One Glass End
Two Glass Ends
Two Glass Ends
1"
(25mm)
4.5" (115mm)
The gas line may be
repositioned to the back.
3.625" (93mm)
(for qualified installers only)
Glass End
The gas line may be
repositioned to the back.
4" (102mm)
Base Inlet
2.5" (64mm)
4150126
Steel End
The gas inlet is
approximately 1/8"
(3mm) above the base
of the fireplace.
6" (153mm)
100-01418