Electrical Input Connection

Do not connect 110-120 VAC to the gas control valve or control system of this fireplace.
The electrical line to the grounded harness inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical connection. Turn the
breaker on only after all wiring is in place (power exhaust, on-off LED harness, etc.).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must supply 120 Volts, 60 Hz, and 7 Amps (maximum draw).
Route the electrical connection through the cover plates and attach to the electrical input wires as
shown below.
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
Caution:
improper and dangerous operation.
HINT: Keep the cover plates disconnected until all wiring to the fireplace is attached. You may also
wish to leave the romex clamps loose until the cover plates are ready to be attached.
Power Exhaust Power Out
Electrical Input
© Travis Industries
Installation
(for qualified installers only)
Inner Cover Plate
(remove to install wire)
Romex Clamp
Grommet
4150126
1/4" Nutdriver
Outer Cover Plate
100-01418
45