The residual (waste) toner is cleared from the ITB surface.
Step 8: ITB cleaning
The ITB cleaning roller and the cleaning brush are applied with DC positive bias to charge the residual toner positive.
As the primary transfer pad is also applied with DC positive bias, the positively charged residual toner is reverse transferred to the photosensitive drum from the
ITB surface.
Positive potential waste toner
Negative potential waste toner
Partition sheet
ITB cleaning brush
DC bias
2.4.1.8 Photosensitive drum cleaning block
The waste toner is cleared from the photosensitive drum surface.
Step 9: Drum cleaning