Simrad VHF Radiotelephones Shipmate RS8400 RS8300 183.2047.005 Rev.I English Warning! The SOS function may only be used in case of emergency and with the correct DSC number coded into the system. The number can be checked by pressing E á 98E for the first five digits and E á97 E for the last five digits.
Manual DISTRESS CALL Select the Distress Channel by pressing the 16 key. Hold down the PTT lever on the handset. MAYDAY MAYDAY MAYDAY State vessel’s name three times THIS IS: Repeat vessel’s name MAYDAY THIS IS: State position of vessel AT POSITION: STATE NATURE OF DISTRESS Release PTT lever.
Automatic DISTRESS CALL (DSC) Caution! The SOS message will alert and activate a rescue operation. To call off a rescue operation, contact your nearest coastal station. The SOS function is blocked until a DSC number is entered - see overleaf for programming of DSC PUSH SOS and ATIS.
Programming of DSC identity number. The DSC number issued by the authori- ties can be programmed directly from the handset. If a mistake is made, the num- ber can be altered for as long as the unit is still ON, but once the power has been switched OFF, the numbers will be fixed in the memory and can only be repro- grammed by an authorized dealer.
Introduction for RS8400, RS8300, RS8300 SD, and RS8300 SOS The VHF system is designed for remote installation of the main unit. Operation is carried out through the waterproof handset, which can be installed up to 20 m (65 ft) from the main unit. Information regarding channel selection, operating mode and output power is al- ways given on the handset display.
Handset Status Displays (International) International Function in standby channels set Private channel Output operative reduced Set is Private channel transmitting operative Channel operative Incorrect ERROR selection CH 10 Key E, access to SHIFT secondary Pre-selected channel functions Scan All Squelch or volume SCAN ALL operative setting...
Page 9
Handset Status Displays (US) channels set weather channels Transmission TX OFF is stopped by time-out...
The ON/OFF switch is fitted at the base of the main unit and a stand-by facility on the handset allows power consumption to be reduced, so that the set can be left on almost indefinitely. Set the ON/OFF switch of the main unit to the ON position.
Position Input (RS8300 SOS only) is automatically updated if you have a GPS navigator connected to the VHF. Without a navigator, the information can be en- tered manually from the keypad via the Position menu. In the Position menu, the display will show the LA XXXXX latitude of the last transferred position from a GPS navigator.
Page 13
UTC 14 39 To enter UTC time in hours and minutes e.g. 14:39 hours. à To acknowledge the position and time input, press the E key. DSC or Digital Selective Calling is a part of the Global Maritime Distress and Safety System - GMDSS.
Channel Selection allows access to all legally permissible channels. It also per- mits direct, single key operation for the distress and general calling frequency, Channel 16. Select the International Distress Channel and General Calling Frequency. Select any public channel, for example, Ship to Ship Channel 77.
International and US channels may be used with this unit, permitting operation in all waters. To toggle between US system and International channels, press the E key and 1 key. If the legend ERROR is displayed, it indicates that US chan- nels are not available.
Output Power can be set to either 1W or to 25W. Squelch is adjustable in three steps from 1 to 3. Volume is adjustable in eight steps from 1 to 8. To reduce output power to 1W for short range transmission.
Dual Watch will automatically monitor Channel 16 as well as one other channel pre-selected by the operator. It will function only if both handsets are in their cradles. Activate/terminate Dual Watch. Monitoring of Channel 16 stops when a handset is lifted from its cradle.
Scan All mode monitors all channels for transmissions. * Squelch must be set above level 1 before this mode can be selected. The Scan function will go in Stand-by mode if the handset is out of its cradle. * In Europe Channel 16 is always monitored. SCAN ALL Activate/terminate Scan All.
Exclusions from Scan All can be made for up to six channels. * This will prevent continuously transmitting stations, such as V.H.F. Direction Beacons, from intruding. * In Europe it is not possible to exclude Channel 16. Set in the number of the channel to be excluded from Scan All programme, e.g.
Scan Programme mode allows a limited number of channels to be monitored. * A minimum of two and a maximum of ten channels can be pre-selected by the operator. * In Europe Channel 16 is always monitored together with the user-selected channels.
Edit of Scan Programme memory. Channels selected for Scan programme will be retained in the memory of the set, even if power is switched off. When the memory is full (ten channels), the first one entered is overwritten by the last one entered.
The Intercom (not available in RS8300 standard) facility allows private conver- sation between the two handsets, or messages over separate loudspeakers, provid- ed there is no radio traffic on the channel selected. Pick up the handset and press the E key and the 2 INTERCOM key to activate Intercom.
Muting completely silences the loudspeakers. Illumination is set to the low level when the handset is switched on. Press the E key and the 4 key to mute the loud- speakers. This setting is automatically cancelled when a handset is replaced in its cradle. Press the E key and the 5 key to adjust the level of illumination.
INSTALLATION POSITION & TIME Interface setup NMEA 0183 GLL, GGA (Green) DATA IN (Red) RETURN Fuse 6.3A slow blow 6.3A Power cable: 1.5m, 2x1.5mm Extendable to max.: 12 V 5m, 2x1.5mm 10m, 2x2.5mm Speaker cable: 1.5m, 2x0.4mm Extendable to max: 20m, 2x0.4mm >20m, 2x0.75mm DUAL SYSTEM...
Page 25
INSTALLATION Installation of transceiver unit, hand- set cradle and watertight socket. (Optional). The transceiver unit is not waterproof, so it will have to be installed in a dry place. 1. Fasten the transceiver unit with the 4 screws (included) in the holes marked A.
Page 26
INSTALLATION Installation of speaker 1. Open the speaker by pressing firmly on the top and bottom of the back part, and at the same time pull the front part forward. 2. Drill out the appropriate holes for instal- lation with a Ø4mm drill. 3.
Page 27
INSTALLATION Ø2mm How to flush mount a speaker 85mm 1. Locate the exact position for the speaker. 2. Cut out the hole as indicated (shaded area). 3. Drill two Ø2mm holes. 4. Fasten with two 3x14mm selftap- ping screws (not included). 5.
Page 28
INSTALLATION Multiple handset connec- tions - up to three handsets can be con- nected simultaneously. Dual outlet for two or more handset sockets. Part no. 157.2014.001 Note! Only one handset should be Intercom connected at a time, as the sockets are in parallel.
OPTIONAL PA-HAILER (not available in RS8300 standard) Installation and operation of PA-HAILER Toggle switch* *Not supplied PA-Hailer horn* Pick up one handset. Place the toggle switch in HAIL position. INTERCOM Select Intercom Press PTT to HAIL Terminate the function by resetting the toggle switch to RS8300 speaker, and place the handset back in its cradle.
TECHNICAL DATA General Power supply: 13.2V dc (12V nominal) isolated earth. Reverse polarity protection. Operating voltage: 10.8 to 15.6V dc Power drain: - receive: 1.8W / 150mA - transmit (25W): 60W / 5A - transmit (1W): 10W / 0.8A - stand-by: 60mW / 5mA Mode: Simplex / Semi Duplex...
Page 31
TECHNICAL DATA Receiver 0.3 µv / 12 dB SINAD Sensitivity: Threshold 10dB quieting max. 2 µv Squelch sensitivity: AF output power: 4W / 8 ohms Headphone output: 0.775v / 600 ohms Construction Main unit: Moisture resistant. Must be located inside, away from possible exposure to water.
INTERNATIONAL MARINE VHF CHANNELS C= Channel D= Duplex o o = Only DK, N, S, SF P= Public H= Harbour n n = Only N, SF S= Ship to Ship X= Receive only u u = Only UK l l = 25 Watt ¤...
US & CANADIAN MARINE VHF CHANNELS •= 25 Watt C= Channel D= Duplex P= Public H= Harbour ¤ ¤ = 1 Watt S= Ship to Ship « « = Receive only u u = USCG only C D P Remarks C D P Remarks •...
Warranty SIMRAD warrants that every product shall be free of defects in material and workmanship as specified below: CATEGORY “A”: *Autopilots *Radars *Instruments *Navigators *Radiotele- phones *Plotters *Gyro compasses *Sonars *Echo sounders *Trawl Instrumenta- tion. These products are warranted for a period of 24 months on parts and 12 months on labour from date of purchase, except for category B items.