EAS00811
4. Thermo switch
8 Remove the thermo switch from the ther-
mostat housing.
8 Connect the pocket tester (Ω × 1) to the
thermo switch 1 as shown.
8 Immerse the thermo switch in a container
filled with coolant2.
8 Place a thermometer3 in the coolant.
8 Slowly heat the coolant, then let it cool
down to the specified temperature.
8 Check the thermo switch for continuity
at the temperatures indicated below.
Test step
Coolant temperature
Thermo switch
1
0 ~56 °C
2
More than65 ± 2 °C
3*
65± 2°C to 56°C
4*
Less than56 °C
Steps 1 & 2: Heating phase
Steps 3 & 4: Cooling phase
3
1
w
8 8 8 8 8 Handle the thermo switch with special
care.
8 8 8 8 8 Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
Thermo switch
23 Nm (2.3 m • kg, 16.6 ft • lb)
Three bond sealock
Continuity
NO
YES
YES
NO
2
®
10
COOLING SYSTEM
A Cooling phase
B Heating phase
8 Does the thermo switch operate prop-
erly as described above?
YES
8-42
-
ELEC
NO
Replace the thermo
switch.
+