Sharp UP-3301 Service Manual page 19

Pos terminal
Hide thumbs Also See for UP-3301:
Table of Contents

Advertisement

No
Procedure on P.C. side
9
Connect P.C. and UP-3301 via RS232 (CH2).
10
Execute "UTL33.EXE" on P.C.
Operation:
>UTL33 T80BP.ROM
("T80BP.ROM" is a file name of S-type object.)
11
Program data is sent to UP-3301 automatically.
12
"UTL33.EXE" is completed.
P.C. shows
"Completed."
<Usage of "UTL33.EXE">
"UTL33.EXE" is a utility program on P.C. - a program that sends the
application program data of UP-3301, the image data of the Logo stamp
of UP-T80BP or the application program data of UP-T80BP in order to
replace them.
Syntax
UTL33 [-Fn] [-Cn] filename [filename ...]
Parameter
filename
Specifies the name file which you want to send.
For UP-3301 IPL
For UP-T80BP LOGO STAMP BMP/PCX file
For UP-T80BP IPL
S-type ROM object file
S-type ROM object file
UP-3301US SERVICE PRECAUTION
No
Procedure on UP-3301 side
5
UP-T80BP enters into IPL mode when the Feed key is pressed.
(UP-T80BP clears the application program which is in its own
flash ROM.)
The ERROR Lamp is blinking and the On-Line Lamp is turned off.
6
UP-T80BP waits the application program data.
The ERROR Lamp is turned off and the On-Line Lamp is
turned on.
7
Enter "UP-T80BP Utility" mode.
Select "6 UP-T80BP Utility" in SRV mode
8
Starting of "UP-T80BP Utility" mode.
UP-3301 shows
UP-T80BP Utility
11
Program data is received from P.C. automatically.
UP-T80BP Utility
IPL mode
The On-line Lamp of UP-T80BP starts blinking.
12
UP-3301 shows
"Completed."
UP-T80BP Utility
IPL mode
The On-line Lamp of UP-T80BP stops blinking.
13
Touch "OK" button.
14
Touch "EXIT" button.
15
Turn OFF the power of UP-3301.
16
Select "Normal Mode" on UP-T80BP.
Set the Bit 1 of DipSwitch 2 to "OFF" to enter "Nomal Mode".
17
Execute "Master Reset" on UP-T80BP.
Switches
-Fn
Specifies the function. Valid values for n are in the range 1 through 3.
1: UP-3301 IPL
2: UP-T80BP LOGO STAMP
3: UP-T80BP IPL
Normally, UTL33.EXE takes the suitable function automatically.
If the automatic selection does not work correctly, please use this
switch.
-Cn
Specifies the number of the serial (COM) port. Valid values for n are
in the range 1 through 2.
The default value is 1 (COM1).
Example
For UP-3301 IPL.
UTL33 3301_1.ROM 3301_2.ROM
For UP-T80BP LOGO STAMP (To use COM2).
UTL33 -C2 LOGO.BMP
For UP-T80BP IPL (To use the switch "-F").
UTL33 -F3 80BP.ROM.
– 17 –