Customer Display - Sharp UP-3301 Service Manual

Pos terminal
Hide thumbs Also See for UP-3301:
Table of Contents

Advertisement

3-6. Extended I/O area
The addresses from F00000h to FFFFFFh are called an extended I/O area. The UP-3301 uses the following addresses as the break address register
(BAR) for SSP.
• FFFF00h ~ FFFFFFh
4. LCD display
The main display is a 640 x 480 dot liquid crystal display.
4-1. Block diagram
Here is the block diagram of the LCD and its associated components.
CPU
H8/510
RD-
WR-
WAITZ
WAIT-
MPCA8
VWAITZ
RFSH-
RESET-
4-2. LCD panel
The dot-matrix LCD unit LM10V33 with color STN and CCFT back light
is used for the LCD panel. The resolution provided is 640 x 480.
4-3. Display controller
The Matsushita VGAC (MN89303A) is used for the display controller.
VRAM is on the address space of the CPU and data can be written on
and read from it by every 128 KB of bank at the address C00000H ~
C1FFFFH from the CPU side. VRAM consists of 4 banks.
4-4. LCD ON control
The LCD's bias power supply is controlled by the MN89303A terminal
LCDON to turn the LCD screen on and off.
The LCDON is at "L" resetting +5V power is supplied to the LCD by set-
ting the expanded function control register bit5 of MN89303A to "H" with
software. The LCD screen isn't turned on until +5V is supplied.
VCC
SD0~SD15
RAS/CAS
SA0~SA16
IORD-
ISP
MEMRD-
2032
IOWR-
MD0~MD15
MEMWR-
Φ
MA0~MA9
CLK
UD0~UD7
LD0~LD7
ISP
READY
2032
RFSH-
MN89393A
LCDON
RESET
VCC
BACKON
UP-3301US CIRCUIT DESCRIPTION
VCC
RAS-/CAS-
WE-
WE-
VRAM
(DRAM512KB)
D0~D7
A0~A9
UD0~UD7
LD0~LD7
LCD
LP
LP
(640 x 480)
FP
YD
DCLK
XCK
VCC
LOGIC
(LCD ON/OFF)
+5V
OSC1
POWER
SUPPLY
OCS2
25MHz
(BACK LIGHT ON/OFF)
Fig. 7
4-5. Back light control
The back light is turned ON/OFF by the MN89303A. The initial value is
"L" and the back light is off. By setting the expanded function control
register bit6 of the MN89303A to "H", the inverter unit is turned on.
4-6. Luminance and contrast adjustment
• Luminance: Luminance is adjusted with an inverter which has a
dimming function.
• Contrast:
Contrast is adjusted by controlling the contrast adjust-
ment voltage (VCON) of the LM10V33.

5. Customer display

The customer display uses the NEW TYPE 2 LINE vacuum fluorescent
tube. The display is turned on and off by the CKDC9.
– 58 –
Contrast
Luminance
INVERTER
+12V

Advertisement

Table of Contents
loading

Table of Contents