Sharp UP-3301 Service Manual page 18

Pos terminal
Hide thumbs Also See for UP-3301:
Table of Contents

Advertisement

4.2 UP-T80BP LOGO
No
Procedure on P.C. side
1
Install "UTL33.EXE" on the P.C.
7
Connect P.C. and UP-3301 via RS232 (CH2).
8
Execute "UTL33.EXE" on P.C.
Operation:
>UTL33 LOGO.BMP
("LOGO.BMP" is a file name of Bit-Map image.)
9
Program data is sent to UP-3301 automatically.
10
"UTL33.EXE" is completed.
P.C. shows
"Completed."
4.3 UP-T80BP IPL
No
Procedure on P.C. side
1
Install "UTL33.EXE" on the P.C.
No
2
Enter the SRV mode. Then turn OFF the power or UP-3301.
3
While pressing the On-Line key, tum ON the power of UP-3301.
Keep pressing the On-Line key, and then press the Feed key
also. (Don't move a finger from the On-line key.)
4
UP-T80BP enters into LOGO mode.
UP-T80BP prints out
"****************".
5
Go into "UP-T80BP Utility mode".
Select "6 UP-T80BP Utility" in SRV mode.
6
Starting of "UP-T80BP Utility mode".
UP-3301 shows
9
Program data is received from P.C. automatically.
10
UP-3301 shows
"Completed."
And UP-T80BP prints out the LOGO image.
11
Touch "OK" button.
12
Touch "EXIT" button.
13
Turn OFF the power of UP-3301.
14
Execute "Master Reset" on UP-T80BP.
No
2
Turn OFF the power of UP-3301.
3
Select "IPL Mode" on UP-T80BP.
Set the Bit 1 of DipSwitch 2 to "ON" to enter "IPL Mode".
4
While pressing both the Feed key and the On-Line key, turn ON
the power of UP-3301.
The ERROR Lamp and the On-line Lamp of UP-T80BP is
blinking.
UP-3301US SERVICE PRECAUTION
– 16 –
Procedure on UP-3301 side
UP-T80BP Utility
EXIT
UP-T80BP Utility
Normal mode
EXIT
UP-T80BP Utility
Normal mode
Complete
EXIT
OK
Procedure on UP-3301 side
IPL SW
ON
IR Filter

Advertisement

Table of Contents
loading

Table of Contents